ECLIPSE 3™ WITH AUTOSAT® PERSONAL OXYGEN SYSTEM (SeQual)
|
|||
SeQual Products 2010 |
|||
- Description
- Features
- Notes
- Request a Quote
- Send to a Friend
Eclipse 3™ with autoSAT® Personal Ambulatory Oxygen System (PAOS)™
Enhanced performance, revolutionary clinical benefits and innovative accessories take the next generation Eclipse to new heights. Its the all-in-one solution for your oxygen business—fulfilling both clinical needs and patient wants.
Adjustable Rise Time Options: Three available rise time options—Fast, Medium and Slow. Adjustable rise time allows the clinician to choose the pulse dose delivery waveform for patient comfort.
Enhanced performance, revolutionary clinical benefits and innovative accessories take the next generation Eclipse to new heights. Its the all-in-one solution for your oxygen business—fulfilling both clinical needs and patient wants.
Adjustable Rise Time Options: Three available rise time options—Fast, Medium and Slow. Adjustable rise time allows the clinician to choose the pulse dose delivery waveform for patient comfort.
- New AC and DC adapters that are smaller in size yet more durable
- New innovative Universal Cart design allows for easy access to battery
- More user-friendly alarm package
- Easy-access service and maintenance information
- In Pulse Dose Mode, if an inspiratory effort is not detected, the device will deliver a continuous flow of oxygen; continually searching for a breath every 15 seconds.
- Adjustable Pulse Dose sensitivity settings
- Approved for Rx of 0.5 – 3.0 LPM continuous flow
- autoSAT Technology
- Pulse Dose volumes up to 96mL (in increments of 16mL) in addition, three new pulse dose volumes of 128mL, 160mL and 192mL
- Three available rise time options—Fast, Medium and Slow
- mL and LPM dose LCD Display
Simple
- One machine for stationary, ambulatory and travel needs
- Offers both continuous flow and pulse dosing options
- Maximum Medicare reimbursement with two billing codes: E1390 & E1392
- The only system on the market that can be upgraded in the field as new technology becomes available
- Longer service intervals with lower maintenance costs
Trusted
- The sleek design is small, quiet and can lower electric bills
- No waiting for cylinder deliveries and replaces bulky equipment
- Simplifies the patients’ continuum of care with one device
- Accessory options that support an active lifestyle
- FAA Approved for commercial airline travel
- AC/DC and battery power options extend therapy time and patient travel
Proven
- Consistently delivers a fixed pulse dose volume up to 96mL (in increments of 16mL) in addition, three new pulse dose volumes of 128mL, 160mL and 192mL
- autoSAT Technology, a pulse delivery system, maintains a consistent pulse dose volume for every breath as your patient’s respiratory rate changes
- Can be used with CPAP and bi-level devices in Continuous Flow
- New control panel displays in either LPM or mL for a more accurate prescription verification
Specifications
- Oxygen output pressure: 5.0 psig (34.5 kPa) nominal
- Oxygen concentration: 90% ± 3% @ sea level
- Power specifications: AC Operation 100-240 VAC, 50-60 Hz; DC Operation 12 V nominal
- Sound level: 48 dB(A) at 3.0 LPM Continuous Flow Mode; 40 dB(A) at 3.0 Pulse Dose setting
- Weight: Eclipse 15 pounds; Power Cartridge 3.4 pounds
- Size H x W x D: 19.3 x 12.3 x 7.1 inches (49.0 x 31.2 x 18.0 cm)
- Pulse Dose settings: 16-96 (16mL increments), 128mL, 160mL, 192mL (measured in mL)
- Continuous Flow settings: 0.5 to 3.0 LPM (0.5 liter increments) (measured in Liters Per Minute LPM)
- Power Cartridge: Quantity (2) 97.5 W-Hr battery packs each containing 7.92 grams of equivalent lithium content
- Power Cartridge: 1.8 to 5.0 hrs, dependent upon the flow recharge time setting, recharge time to achieve 80% capacity from a fully discharged Power Cartridge
- Back up alarm power: 9 Volt battery
- Power Consumption: 52 watts at 1.0 LPM continuous flow; 145 watts at 3.0 LPM continuous flow; 45 watts at 1.0 pulse dose setting; 95 watts at 6.0 pulse dose setting
- Nominal Power Cartridge operating time: 2.0 hours at 2.0 LPM continuous flow; 1.3 hours at 3.0 LPM continuous flow; 5.2 hours at 2.0 pulse dose setting,12bpm; 3.5 hours at 6.0 pulse dose setting,12bpm
- Trigger sensitivity: Adjustable between -0.125 cm H2O to -0.40 cm H2O
- Altitude operating range: 0-13,123 feet (0-4000 meters)
- Oxygen concentration indicator: Green Light = Normal Operation; Yellow Light = Warning or Caution; Red Light Flashing = Abnormal Operation
- Operating temperature: 50° F to 104° F (10° C to 40° C) at 82.4° F (28° C) dew point, non-condensing
Alarms
- No inspiration detected in
- Pulse Dose Mode
- Unit Malfunction
- Oxygen flow outside normal limits
- Loss of power
- Low Power Cartridge
- Low Therapeutic Oxygen Output
The Eclipse Oxygen System consists of Concentrator, Power Cartridge, AC Power Supply, DC Power Supply and Cart with telescoping handle.